Tel:400-968-7988    021-33779008
Anti-Exendin-4 ABS 012-35
品牌:
貨號:ABS 012-35
規格:200 μg
貨期:

Anti-Exendin-4

商品詳情 參考文獻 相關資料
Cat. No.
ABS 012-35
Product name
Anti-Exendin-4
Description

Mouse monoclonal antibody

Specificity

Specific for exendin-4. No cross-reactivity with GLP-1, GLP-2 (human) or glucagon coated on ELISA wells.

Immunogen

Synthetic exendin-4?

Application
ELISA
Species reactivity (positive)
Human
Species reactivity (negative)
Not determined
Subclass

IgG1/k

Gene ID
2740
Clone number
35
Epitope

The epitope is in the 9-39 region of the peptide, and the antibody cross-reacts strongly with exendin (9-39)amide.

Content

Available in 200 μL and 1 mL size.1 mg/mL +/- 15%. See Certificate of Analysis for details.

Purification
Protein-A purified
Form
Liquid
Solvent
0.01 M phosphate buffer, pH 7.4, containing 0.5 M NaCl and 15 mM sodium azide
Storage
4-8oC without exposure to light. No precautions necessary during handling.
Target

Exendin-4 is a 39 amino acid peptide found in venom from the Gila monster Heloderma suspectum. It is a member of the glucagon-secretin family of peptide hormones and neuropeptides. Exendin-4 is a potent agonist of the GLP-1 receptor and hence a potent stimulator of insulin secretion.

Application 1
ELISA
ABS 012-35 binds to exendin-4 when coated on ELISA wells and reacts specifically with exendin-4 in solution giving a Ka of 1.1x10E9 in an inhibition ELISA. The binding between ABS 012-35 and exendin-4 is disrupted by 4.5 M MgCl2.
ABS 012-35 (as biotinylated detection antibody) forms a sandwich ELISA pair with ABS 033-10 (as capture antibody) for measuring exendin-4, giving a detection limit of as little as 40 pmol/L in an unoptimized buffer assay (1).
By using the above monoclonal antibodies, it is possible to measure intact exendin-4 by a sandwich ELISA which is not subject to interference from GLP-1 or other glucagon-related peptides that may be present. ABS 033-10 is used as capture antibody in combination with a biotinylated detection antibody from the ABS 012 series. The best sensitivity in an unoptimized buffer assay was obtained with biotinylated ABS 012-35 as the detection antibody.

1. Murphy RE, Kinhikar AG, Shields MJ, Rosario JD, Preston R, Levin N, Ward GH (2010) Combined use of immunoassay and two-dimensional liquid chromatography mass spectrometry for the detection and identification of metabolites from biotherapeutic pharmacokinetic samples. Journal of Pharmaceutical and Biomedical Analysis 53:221-227.

20547023
熱銷產品
熱銷產品排行榜
  • 關于我們
  • 購物流程
  • 支付方式
  • 配送方式

請打開QQ掃碼聯系
Copyright@ 2003-2025  進口試劑采購網版權所有     

BIOLEAF熱搜   BIOLEAF試劑盒   BIOLEAF ELISA   BIOLEAF試劑   BIOLEAF品牌   BIOLEAF抗體   BIOLEAF耗材   BIOLEAF小儀器

sitemap   細胞庫查詢   危險品圖標

本公司網站所展示銷售的產品僅供科研!

         滬ICP備08023583號-6     
產品咨詢
QQ掃碼溝通
在線客服
服務電話
400-968-7988
掃碼關注
微信公眾號二維碼

滬公網安備 31011202007338號